Abstract
We report our preliminary experience with the use of fibrin sealant to manage iatrogenic urinary tract injuries, complex urinary fistulas, and urological surgical complications. Topical fibrin sealant was used in 19 patients for iatrogenic urinary tract injury during gynecological or general surgical procedures (7), complex urinary fistulas (5) or urological surgical complications (7). Successful resolution of the injury, fistula or complication was attained after a single application of fibrin sealant in the 18 patients (94.7%) in whom a direct injection technique was used. The only failure (formation of a vesicovaginal fistula) occurred with the air driven sprayed sealant delivery technique after sutured closure of iatrogenic cystotomy during vaginal hysterectomy. Liquid fibrin sealant appears to be safe and prudent for use in urological "damage control" from trauma, fistulas or surgical complications. Direct injection over a sutured urinary anastomosis appears to be highly effective in preventing urinary drainage. Additional study is needed to define further the role and best use of tissue adhesives in urology.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.