Abstract

Sprayed steel fibre reinforced concrete (SSFRC) is a material that tends to present anisotropy, due to the action of the spraying process inducing preferential fibre orientation. Despite numerous applications worldwide since the 1980s, no study has been found of the assessment of fibre distribution and its influence on the residual tensile strength of SSFRC. This work addresess this issue from a quantitative standpoint through an experimental programme with specimens extracted in various orientations within a SSFRC panel. The fibre content and 3D orientation were quantified using the inductive method and correlated with an indirect tensile behaviour for the same specimen with the Barcelona test. The results confirm the high level of anisotropy of SSFRC. The fibre orientation number parallel to the spraying direction is three times bigger than that found in the perpendicular direction. Similar differences were observed between the residual tensile response measured in those directions. Comparison of test results suggest that the preferential fibre orientation creates weaker planes that favours the increase of crack opening at lower load levels.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.