Abstract
The debate continues as to whether a fiberoptic bronchoscope must be used to position a double-lumen tube. This review supports the argument that although bronchoscopy is extremely helpful, it is not always needed for the routine placement of left double-lumen tubes. Several recent clinical reports have demonstrated that an experienced anesthesiologist can safely and consistently position double-lumen tubes without bronchoscopic assistance. In order to do so several important factors must be considered. These include the appropriate choice of tube (left or right), size of tube, and endpoint for the depth of insertion. Although bronchoscopy is useful, no double-lumen tube positioning method is fail-safe. The choice of which approach to use, 'blind' versus fiberoptic bronchoscope-assisted, is influenced by many factors. Operator experience with any method increases the likelihood of success. A fiberoptic bronchoscope is not always needed for left double-lumen tube placement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.