Abstract
In this paper, we report a tapered thin-core fiber based in-line Mach-Zehnder interferometer to improve the response of axial-strain. With the varied diameters of taper waist, the light field distributions are studied by beam propagation method, and the structures are fabricated by arc-discharged lateral offset splicing and tapering techniques. The comprehensive tests are then conducted and compared in terms of axial-strain and temperature. The experimental results show that, by reducing the diameter of taper waist, more than 400% enhancement of wavelength sensitivity can be gained, and the maximum reaches 4.07 pm/µε with the measured error of 3.6%. Moreover, owing to high consistency of temperature response, the near-zero crosstalk is presented by differential compensation method. Furthermore, owing to the merit of high repeatability and stability, our sensor is very practical and promising in the high-precision measurement and engineering monitoring.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.