Abstract

A novel fiber optic vibration sensor is presented, based on the motion detection of an elastic cantilever by means of the optical triangulation technique. The sensor was designed to work at a fixed frequency of 100 Hz for applications in high power electrical plants where insulation and EM immunity requirements make fiber optic sensing the most suitable choice. The working linear range reaches a peak amplitude of 0.25 mm; resolution is 0.1 microm; accuracy is better than +/-3%; and sensitivity is 10 mV/microm. Design details and experimental results are reported.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.