Abstract
In this paper, a novel method used for Fabry-Perot cavity length's demodulation in high-speed and large scope measurement was proposed. Principle of the method is based on uniqueness of intensity of multiple wavelengths in the scope of Fabry-Perot vibration. This technique offers flexibility of selecting incident wave length and enhances the scope of demodulation of cavity length, compared with that popular triple wave length demodulation. In experiment, multi-wavelength demodulation is demonstrated for measurement of cavity length varying from 110um to 115um and the strain resolution was higher than 0.1um.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.