Abstract

A fiber-optic evanescent-wave absorption sensor was constructed on the basis of an organofunctionalized silica cladding. The cladding material was prepared by the sol-gel processing of an organofunctional silicon alkoxide, which contains a propyl-ethylenediamine triacetate (PEDTA) group. The PEDTA group can chelate with a Cu(II) ion to form a colored complex. Because of the large formation constant of the complexation reaction, a kinetic approach was used to quantify the Cu(II) content in samples. The sensor has a dynamic range of 0.5–100 ppm and a detection limit of 56 ppb. The measurement of the Cu(II) content in a scattering medium has also been demonstrated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.