Abstract

An all-metal 3-component optical fiber seismometer was proposed and experimentally demonstrated. The theoretical analysis was given based on the electro-mechanical theory. Calibration results showed that the axis sensitivity was about 41 dB (re: 0 dB=1 rad/g) with a fluctuation ±2 dB in the frequency bandwidth of 5 Hz–400 Hz. A transverse sensitivity of about −40 dB was achieved. The fluctuation of the acceleration sensitivity for the three accelerometers in the seismometer was within ±2.5 dB. The minimum phase demodulation detection accuracy of the phase-generated carrier (PGC) was 10−5 rad/√Hz, and the minimum detectable acceleration was calculated to be 90 ng/√Hz.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.