Abstract
Many modern microelectronic chips contain embedded memory arrays. A typical memory bit-cell contains several transistors. Failure of a single transistor or contact within a bit cell makes the entire bit cell inoperable. A dual-beam Focused Ion Beam (FIB) tool combines milling capability with in situ Scanning Electron Microscope (SEM) imaging, which is very useful for identifying the root cause when a physical defect is present. This paper describes the slice-and-view FIB technique for failure analysis (FA) in memory arrays. Several failure mechanisms have been identified, including missing patterns, killer particle defects, shorted and open stack vias. Transmission Electron Microscopy (TEM)/Scanning TEM (STEM) analysis was able to provide additional information when SEM resolution was not sufficient. Processes were adjusted appropriately leading to yield enhancement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.