Abstract
We studied the ability of MRI to predict fetal shoulder width (FSW). In 30 patients referred for MR pelvimetry, measurement of FSW was performed and compared with caliper measurements at term. We report here the feasibility of a method using axial and coronal MR images oriented to the fetal body axes. Shoulder width by MRI (mean = 12.76 +/- 1.42 cm) correlated significantly with postnatal orthopedic caliper measurements (mean = 12.99 +/- 1.37 cm; r = 0.955, SEE = 4.29 mm, p = 0.00001) and with birth weight (r = 0.63, p = 0.0005). Mean paired differences showed a statistically significant 2.3 +/- 4.2 mm underestimation of FSW by MRI (p = 0.01). This reasonably quick nonionizing technique seems to have the potential for evaluating shoulder dystocia and deserves further evaluation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.