Abstract

Objective: This study was designed to assess the changes in fetal oxygen saturation (FSpo2) using fetal pulse oximetry when the fetal heart rate (FHR) monitoring became abnormal during stage II of labour. Study design: FSpo2 was recorded with the Nellcor N400 Oximeter (FS-14 sensor) and was averaged over the last 10 min of the second stage of labour. Second stage FHR patterns were assessed according to Melchior's classification. Results: In terms of FHR patterns, FSpo2-10″ measured 41.4% in type 0 (n=5), 42.4% in type 1 (n=19), 43.3% in type 2 (n=6), 34.0% in type 3 (n=4) and 27.6% in type 4 (n=7) (P=0.03). Conclusions: FSpo2-10″ decreases in cases of severe FHR abnormality during the second stage of labour and could help to decide whether to perform an instrumental extraction.© 1997 Elsevier Science Ireland Ltd.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.