Abstract

BackgroundMonochorionic (MC) twin pregnancies may be complicated by placental pathologies that impact fetal cardiac function, such as twin-twin transfusion syndrome (TTTS) and selective intrauterine growth-restriction (sIUGR). In the TTTS, the unbalanced blood flow through placental anastomoses lead a recipient volume overload, hypertension and hypertrophic cardiomyopathy and the donor twin experiences hypovolemia and hypertension due to increased placental resistance and poor renal perfusion. When MC pregnancies were complicated by sIUGR, the increase of placental resistances lead to complex fetal compensatory mechanisms with redistribution of cardiac output to vital organs. Increased placental vascular resistances, hypoxia and hemodynamic compensation mechanisms lead to higher pre and/or afterload for both ventricles, right cardiac failure and eventually left cardiac failure observed just before fetal death. ObjectivesThe purpose of this study was to describe the anomalies of umbilical, ductal and aortic isthmic Doppler as well as left and right myocardial performance index (MPI) across various clinical phenotypes of MC twin pregnancies, uncomplicated or complicated by TTTS or sIUGR, in order to help differentiating these conditions and to improve the understanding of TTTS and sIUGR pathophysiology. Study designAortic isthmic systolic index (ISI), umbilical artery pulsatility index (UAPI), ductus venosus pulsatility index (DVPI), and MPI were studied in uncomplicated MC twins (control group) and cases of sIUGR or TTTS. ResultsThe measurements were obtained in 113 pregnancies (24 uncomplicated, 22 sIUGR, 51 TTTS). In comparison with controls, the sIUGR smaller twin sets had lower ISI and higher UAPI, and the larger twin had higher ISI. The TTTS donor and recipient had lower ISI, higher UAPI and DVPI. Compared to the co-twin, the ISI values were lower in the sIUGR smaller twin and the TTTS donor had lower ISI and MPI. Comparing TTTS and sIUGR, the recipient had higher DVPI and MPI than the sIUGR larger twin. ConclusionsThe Doppler anomalies observed in the smaller twin reflected increased placental blood flow resistance, presumably due to abnormal feto-fetal transfusion in TTTS and to unequal placental sharing in sIUGR. Early hemodynamic changes suggestive of cardiac overload in the recipient twin may help to differentiate TTTS and sIUGR.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call