Abstract
Fetal assessment following preterm prelabour rupture of membranes (PPROM) may result in earlier delivery due to earlier detection of fetal compromise. However, early delivery may not always be in the fetal or maternal interest, and the effectiveness of different fetal assessment methods in improving neonatal and maternal outcomes is uncertain. To study the effectiveness of fetal assessment methods for improving neonatal and maternal outcomes in PPROM. Examples of fetal assessment methods that would be eligible for inclusion in this review include fetal cardiotocography, fetal movement counting and Doppler ultrasound. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 June 2014) and reference lists of retrieved studies. Randomised controlled trials comparing any fetal assessment methods, or comparing one fetal assessment method to no assessment. Two review authors independently assessed trials for inclusion into the review. The same two review authors independently assessed trial quality and independently extracted data. Data were checked for accuracy. We included three studies involving 275 women (data reported for 271) with PPROM at up to 34 weeks' gestation. All three studies were conducted in the United States. Each study investigated different methods of fetal assessment. One study compared weekly endovaginal ultrasound scans with no assessment (n = 93), one compared amniocentesis with no assessment (n = 47), and one compared daily nonstress testing with daily modified biophysical profiling (n = 135). We were unable to perform a meta-analysis, but were able to report data from individual studies.There was no convincing evidence of increased risk of neonatal death in the group receiving endovaginal ultrasound scans compared with the group receiving no assessment (risk ratio (RR) 7.30, 95% confidence interval (CI) 0.39 to 137.54; one study, 92 women), or in the group receiving amniocentesis compared with the group receiving no amniocentesis (RR 1.00, 95% CI 0.07 to 15.00; one study, 44 women). For both these interventions, we inferred that there were no fetal deaths in the intervention or control groups. The study comparing daily nonstress testing with daily modified biophysical profiling did not report fetal or neonatal death. Primary outcomes of maternal death and serious maternal morbidity were not reported in any study. Overall, there were few statistically significant differences in outcomes between the comparisons.The overall quality of evidence is poor, because participant blinding was not possible for any study. There is insufficient evidence on the benefits and harms of fetal assessment methods for improving neonatal and maternal outcomes in women with PPROM to draw firm conclusions. The overall quality of evidence that does exist is poor.Further high-quality randomised controlled trials are required to guide clinical practice.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.