Abstract
Tumor response assessments on positron emission tomography (PET)/magnetic resonance imaging (MRI) scans require correct quantification of radiotracer uptake in tumors and normal organs. Historically, MRI scans have been enhanced with gadolinium (Gd)-based contrast agents, which are now controversial due to brain deposition. Recently, ferumoxytol nanoparticles have been identified as an alternative to Gd-based contrast agents because they provide strong tissue enhancement on MR images but are not deposited in the brain. However, it is not known if the strong T1- and T2-contrast obtained with iron oxide nanoparticles such as ferumoxytol could affect MR-based attenuation correction of PET data. The purpose of our study was to investigate if ferumoxytol administration prior to a 2-deoxy-2-[18F]fluoro-D-glucose [18F]FDG PET/MR scan would change standardized uptake values (SUV) of normal organs. Thirty pediatric patients (6-18years) with malignant tumors underwent [18F]FDG-PET/MR scans (dose 3MBq/kg). Fifteen patients received an intravenous ferumoxytol injection (5mgFe/kg) prior to the [18F]FDG-PET/MR scans (group 1). Fifteen additional age- and sex-matched patients received unenhanced [18F]FDG-PET/MR scans (group 2). For attenuation correction of PET data, we used a Dixon-based gradient echo sequence (TR 4.2ms, TE 1.1, 2.3ms, FA 5), which accounted for soft tissue, lung, fat, and background air. We used a mixed linear effects model to compare the tissue MRI enhancement, quantified as the signal-to-noise ratio (SNR), as well as tissue radiotracer signal, quantified as SUVmean and SUVmax, between group 1 and group 2. Alpha was assumed at 0.05. The MRI enhancement of the blood and solid extra-cerebral organs, quantified as SNR, was significantly higher on ferumoxytol-enhanced MRI scans compared to unenhanced scans (p < 0.001). However, SUVmean and SUVmax values, corrected based on the patients' body weight or body surface area, were not significantly different between the two groups (p > 0.05). Ferumoxytol administration prior to a [18F]FDG PET/MR scan did not change standardized uptake values (SUV) of solid extra-cerebral organs. This is important, because it allows injection of ferumoxytol contrast prior to a PET/MRI procedure and, thereby, significantly accelerates image acquisition times.
Accepted Version
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.