Gas composition detection and analysis in high-pressure environments, such as those encountered in combustors, power plants, and planetary bodies, are important for scientific and engineering research. Conventional laser-based sensing using nanosecond (ns)-laser-induced breakdown spectroscopy (ns-LIBS) remains unreliable at elevated pressures because of the relatively high measurement uncertainty. To circumvent this problem, we propose to employ femtosecond-laser-induced plasma spectroscopy (FLIPS) to achieve a stable and reliable gas sensing at elevated pressures. A comprehensive study on the differences in the measurement quality of FLIPS and ns-LIBS for high-pressure nitrogen gas is conducted. The results show that the signal level and stability of ns-LIBS significantly decrease with the increase in pressure. In contrast, the signal level of FLIPS increases with the increase in pressure while maintaining the stability in the pressure range of 1–40 bar. In addition to the superior measurement stability, the FLIPS measurement provides a longer probe length (∼3 times compared to ns-LIBS) with a higher data acquisition speed (100 times compared to 10-Hz ns-LIBS).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.