Abstract
Background:Interference screw is a popular fixation device used to rigidly fix bone-patellar tendon-bone (B-PT-B) graft both in femoral and tibial tunnels in anterior cruciate ligament (ACL) reconstruction. Parallel placement of screw is difficult in transtibially drilled femoral tunnel but always desired as it affects pullout strength of the graft. Commonly, interference screw into the femoral tunnel is inserted through the anteromedial (AM) or accessory AM portal. These portals are not-in-line with the transtibially drilled femoral tunnel. Furthermore, these portals increase the divergence of the interference screw in the femoral tunnel. We hypothesized that interference screw placement through patellar tendon (PT) portal (through donor defect) in transtibially drilled femoral tunnel can be less divergent. We report the prospective randomized study to investigate the difference of divergence of interference screw placed through PT portal and AM portal and its clinical relevance.Materials and Methods:Forty-one patients underwent femoral tunnel B-PT-B graft fixation through AM portal (group 1) and other 41 (group 2) through PT portal. Femoral tunnel-interference screw divergence was measured on postoperative digital lateral X-rays. Ha’s method was used to grade divergence. The clinical outcome was assessed by postoperative intervention knee documentation committee grading (IKDC) and Lysholm score at 2 years followup.Results:Mean tunnel-screw divergence in sagittal plane through AM portal was 13.38° (95% CI: 12.34-14.41) and through PT portal was 7.20° (95% CI: 6.25-8.16) (P<0.0001). In AM portal group, 82.9% patients had divergence in either grade 3 or 4 category, whereas in PT portal group, 82.9% patients were in grade 1 or 2 category (P<0.0001). Mean Lysholm score were 92.8 and 94.5 at two-year follow-up in both groups which were statistically not significant. The International knee documentation committee grades of patients in both groups were similar and had no statistical significance.Conclusion:Femoral interference screw placement through the PT portal leads to significantly less screw divergence as compared with screw placement through the AM portal. However, this difference in divergence is not reflected in clinical outcome.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.