Abstract

We report a case in which cement protrusion into the pelvis led to a major complication. During reaming and preparation of the anterosuperior acetabulum, a bony defect resulted which made fixation of an uncemented cup impossible, and a cemented polyethylene cup was used instead. After surgery the patient suffered a complete loss of femoral nerve function. Postoperative X-rays and CTs showed that a huge mass of bone cement protruded into the pelvis in close proximity to the iliac vessels and the femoral nerve. This probably led to nerve damage during the cement's polymerisation process due to the heat.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.