Abstract

Preserving femoral head vascularity during hip resurfacing may avoid femoral neck fractures and late femoral loosening. The posterior approach and notching of the femoral neck influence femoral head perfusion. However, it is not known if standard preparation of the femoral head during hip resurfacing can disrupt blood flow. Ten patients (10 hips) with advanced osteoarthritis having metal-on-metal hip resurfacing by means of a vascular-preserving surgical approach had femoral head blood flow measurements using laser Doppler flowmetry. Nine hips had a mean decrease of 70% in femoral head blood flow after standard reaming and preparation. The data suggest femoral head reaming during hip resurfacing substantially impacts blood flow to the femoral head and infers the extra osseous blood supply is still important in the arthritic femoral head. To avoid damaging the retinacular vessels, surgeons should direct the cylindrical reamer superolaterally staying as close as possible to the inferomedial neck.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.