Abstract

A case of postoperative fracture in the donor femur after obtaining autologous bone graft with a reamer/irrigator/aspirator is presented. This procedure was successful in healing a difficult femoral nonunion, but the patient sustained a fracture of the contralateral (bone graft donor) femur 20 days after surgery. A mechanical analysis is conducted of this case and recommendations are made. Unrestricted weightbearing on a limb that has undergone reamer/irrigator/aspirator bone graft harvesting, particularly in a noncompliant patient, is probably inadvisable. If possible, one should obtain bone graft from the same limb as the fracture being treated because this will leave the patient with one unaltered limb for mobilization.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.