Abstract

False aneurysm formation is a major complication of vascular surgery. The most frequent site of anastomotic false aneurysm formation is the femoral artery. Between January 1974 and June 1986, 26 patients with 42 femoral false aneurysms were treated at the Princess Alexandra Hospital. Aneurysms developed following Dacron arterial grafting (29 aneurysms), saphenous vein grafting (10 aneurysms), umbilical vein grafting (one aneurysm) and femoral embolectomy (two aneurysms). Arterial wall failure (with intact suture and graft) was the most frequent operative finding. Ten recurrent aneurysms developed. There was a significantly greater number of recurrences when resuture or patch repair was employed than when an interposition graft was used as a repair. The development of a femoral anastomotic false aneurysm should be viewed as a total failure of that anastomosis and repair should be by replacement with an interposition graft rather than repair of the failed anastomosis by suture or patch.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.