Abstract
This paper addresses the question of the morphological dependence of counting efficiency curves for in vivo lung monitoring of workers, with a particular focus on the case of female workers for whom different chest girth and cup size are considered. A library of 24 female torsos, with chest girth varying from 85 to 120 and cup size from A to F, was constructed using mesh and NURBS formats. The anatomical realism and usefulness of these models for simulating in vivo counting measurements are illustrated and simulations are reported for a typical 4-germanium (Ge) counting system. A simple analytic formula describing the relation between efficiency curves obtained for each female phantom is given. This formula uses the mass attenuation coefficient for adipose tissue and two parameters which are dependant on lung volume and breast weight. The model is tested against Monte Carlo simulated data, experimental data obtained with the Livermore phantom and published data. The model correctly describes the efficiency curve and, since the parameters depend on the counting geometry, it is shown how to estimate them from experimental measurements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.