Abstract
Primary aluminium production is a high-energy consumption process, and improving the energy efficiency of smelters could be economically viable. An issue in the Hall–Héroult prebake anode technology is the voltage drop in the anode connector caused by the thermo-electro-mechanical interface contact between steel stub, carbon anode, and cast iron thimble. Steel stubs are exposed to an extremely aggressive environment throughout their service life, involving thermomechanical stresses and chemical attacks that cause shape changes. To estimate voltage drop due to change in stub shape, a 3D finite element model (FEM) of a whole anode was developed and solved with the in-house code FESh++. Steel stub diameter variations were compared with a new stub configuration. Results show a voltage increase of about 10mV between new and damaged configuration simulations. This holds promising potential for improving energy efficiency. An experimental factorial design was used to determine the main factor in steel stub diameter variation affecting voltage drop in the anode connector assembly.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.