Abstract
High penetration of wind power requires reliable wind energy generation. A successful low-voltage ride-through (LVRT) scheme is a key requirement to achieve reliable and uninterrupted electrical power generation for wind turbines equipped with doubly fed induction generators (DFIGs). This paper proposes a feed-forward transient current control (FFTCC) scheme for the rotor side converter (RSC) of a DFIG to enhance its LVRT capability. This new control scheme introduces additional feed-forward transient compensations to a conventional current regulator. When three phase faults occur, these compensation terms correctly align the RSC ac-side output voltage with the transient-induced voltage, resulting in minimum transient rotor current and minimum occurrence of crowbar interruptions. With little additional computational effort, the proposed control scheme helps relieve the transient current stress on the RSC and helps maintain an uninterrupted active and reactive power supply from the wind turbines to the power grid. Simulation results are shown to demonstrate the effectiveness of the proposed FFTCC scheme in suppressing transient rotor currents.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.