Abstract

A feasibility study for reclamation of a secondary treated sewage effluent mainly from industrial sources (60%) in Singapore has been conducted using a dual membrane UF-RO process. The pilot system had a treatment capacity of 2 m 3/h. The UF unit and RO unit were operated at 70–80% and 40% water recovery, respectively. Six-month run for the pilot was carried out to study the stability and fouling tendency of membranes. The characteristics of the raw feed indicated that ammonia-N was consistently high at 30–50 mg/L. Very high fluctuations in iron (0.3–3.7 mg/L), turbidity (1–27.1 NTU) and TOC (3.2–56.7 mg/L) were observed. Nitrate was low at <0.2 mg/L. The results of the study showed that dosage of alum in the UF process significantly reduced organic foulants and phosphate scalants. The polymeric RO membrane could tolerate organics from industrial wastewater and performed >96% salt rejection at the end of the study after 6 months. The study concluded the dual membrane process was capable of reclaiming the sewage effluent mainly from industrial sources for industrial use.