Abstract
It is important to assess fiber orientation, material properties and part defect because strength and stiffness of composites depend on fiber orientation of CFRP (carbon fiber reinforced plastics). A one-sided pitch–catch setup was used in the detection and evaluation of ultrasonic wave behavior and fiber orientation in the unidirectional CFRP composite laminates. Two Rayleigh wave transducers were joined head-to-head and used in the pitch–catch mode on the surface of the composites. The pitch–catch signal was found to be more sensitive than normal incidence backwall echo of longitudinal wave to subtle flaw conditions in the composite. Especially, one-sided ultrasonic measurement was made with using a Rayleigh wave transducers and the Rayleigh ultrasonic waves were extensively characterized in the CFRP composite laminates. Also, a conventional scanner was used in an immersion tank for extracting fiber orientation information in the unidirectional laminate. Therefore, it is thought that the proposed method is useful to evaluate integrity of CFRP laminates.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.