Abstract

Water seepage in concrete threatens the safety of marine constructions and reduces the durability of concrete structures. This note presents a smart aggregate-based monitoring method to monitor the travel time evolution of a harmonic stress wave during the water infiltrating process in concrete structures. An experimental investigation, in which two plain concrete columns were examined under different water infiltration cases, verified the validity of the proposed monitoring method. The test results show that the travel time of the harmonic stress wave is sensitive to the development of water seepage in concrete and decreases with increasing water seepage depth. The proposed active monitoring method provides an innovative approach to monitor water seepage in concrete structures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.