Abstract

BackgroundSingle-element focused transducers applied in blood-brain barrier (BBB) disruption experiments to optimize intravascular therapies in CNS diseases have the advantage of low cost and portability. Most of the in vivo studies on non-human primates report the use of single-element transducers with an annular spherical shape and a central frequency of 500 kHz. High-frequency ultrasound has smaller focal area and less standing-wave effect but lower transcranial penetration efficiency. Our study reports the feasibility and safety concerns of BBB opening by single-element spherical transducers with central frequencies of 300, 650 and 800 kHz on two rhesus macaques. MethodsPulsed ultrasound exposure (3-minute duration, 0.5–1% duty cycle) combined with microbubble injection (SonoVue, 0.2uL/g) was used to disrupt the BBB of the monkeys under the magnetic resonance imaging (MRI) guidance. Gadolinium contrast-enhanced MRI was used to confirm and evaluate the BBB opening after sonication. T2-weighted fast spin echo and T2 * -weighted gradient echo sequences were used to check the post-sonication complications, such as edema and micro-bleeding. ResultsContrast enhancement was found on the post-sonication T1 weighted images for all experiments, showing that the BBB was successfully opened under all the three frequencies on both monkeys. The enhanced area was largest at the lowest frequency. No obvious hypo-intensity or hyper-intensity was observed on either the T2 * weighted gradient echo images or T2-weighted fast-spin echo images, implying the safety of the opening procedure. However, signal enhancement was also observed in the subarachnoid space of the sulci for all frequencies, indicating that the BBB was also disrupted in the propagation path outside the focal area. ConclusionsThe feasibility of BBB opening with single-element transducer under frequencies ranging from 300 kHz to 800 kHz was confirmed by experiments in two non-human primates in vivo. Further investigation into the off-target effects and transducer configurations is needed for safety optimization.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.