Abstract

The present study aimed to develop a reliable dynamic measurement technique, which can be used directly in the outpatient setting, based on dorsal subluxation of the scaphoid on scaphoid shift test. This study was designed to evaluate feasibility and to quantify dorsal subluxation of the scaphoid in relation to the lunate. Based on a scaphoid shift test under ultrasonography, a standardized 3D test model was developed to measure subluxation. Sagittal subluxation ranged between 0 and 6 mm, as checked on the implemented scale. Four hand surgeons trained in ultrasonography (experience level II–V) performed blinded measurements (total of 52, n = 13 per investigator) with a standardized measurement protocol. Dorsal subluxation of the scaphoid was measured in relation to the lunate. Interobserver reliability on intraclass correlation coefficient (ICC) was excellent, at 0.97 (95% confidence interval, 0.930–0.992). Mean overall absolute measurement error was 0.27 mm ± 0.21. Dorsal subluxation of the scaphoid can thus be accurately measured on ultrasound with excellent interobserver reliability, quantifying and improving clinical assessment of scapholunate instability.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.