Abstract

We would like to evaluate the effectiveness of Tomotherapy for decreasing radiation dose to the cochlea in head and neck cancer patients. A retrospective review of 72 patients undergoing radiation for head and neck cancer was performed. Cochlea dose was compared between 20 patients treated with conventional intensity modulated radiotherapy (IMRT) and 52 treated with Tomotherapy. A review of literature was performed to assess cochlea dose reported with the IMRT technique for head and neck cancer. Mean total cochlea dose was 36 Gy for IMRT compared to 12.1 Gy for Tomotherapy (p=0.002). Mean right cochlea dose was respectively, 16.6 and 6.2 Gy for IMRT and Tomotherapy (p=0.007), and 19.3 and 5.9 Gy for the left. Cochlea (p=0.002). Mean cochlea dose reported in the literature ranged from 16 to 55 Gy with IMRT for head and neck cancer. Helical Tomotherapy for head and neck cancer may significantly decrease radiation dose to the cochlea without sacrificing target volume coverage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.