Abstract

ObjectiveTo evaluate the feasibility of five-dimensional Long Bone (5D LB), a new technique that automatically archives, reconstructs images, and measures lengths of fetal long bones, to assess whether the direction of volume sweep influences fetal long bone measurements in three-dimensional (3D) ultrasound and 5D LB, and to compare measurements of fetal long bone lengths obtained with 5D LB and those obtained with conventional two-dimensional (2D) and manual 3D techniques.MethodsThis prospective study included 39 singleton pregnancies at 26+0 to 32+0 weeks of gestation. Multiple pregnancies, fetuses with multiple congenital anomalies, and mothers with underlying medical diseases were excluded. Fetal long bones of the lower extremities-the femur, tibia, and fibula were measured by 2D and 3D ultrasound, and 5D LB, by an expert and non-expert examiner. First, we analyzed the 3D ultrasound and 5D LB data according to 2 different sweeping angles. We analyzed intra- and inter-observer variability and agreement between ultrasound techniques. Paired t-test, interclass correlation coefficient, and Bland-Altman plot and Passing-Bablok regression were used for statistical analysis.ResultsThere was no statistical difference between long bone measurements analyzed according to 2 different volume-sweeping angles by 3D ultrasound and 5D LB. Intra- and inter-observer variability were not significantly different among all 3 ultrasound techniques. Comparing 2D ultrasound and 5D LB, the interclass correlation coefficient for femur, tibia, and fibula was 0.91, 0.92, and 0.89, respectively.Conclusion5D LB is reproducible and comparable with conventional 2D and 3D ultrasound techniques for fetal long bone measurement.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call