Abstract

Backgound/Purpose: Evaluation of the feasibility of thoracoscopic correction of esophageal atresia with distal fistula. Methods: Eight consecutive neonates with esophageal atresia and distal fistula were treated thoracoscopically. Mean birth weight was 3,048 g (range, 2,140 to 3,770). The patients were intubated endotracheally and placed in a¾ left prone position. Three cannulae were inserted along the inferior tip of the scapula. CO2 was insufflated at a pressure of 5mm Hg and a flow of 0.5 L/min. The fistula was either clipped or ligated. The proximal esophagus was opened and an anastomosis was made over a 6F or 8F nasogastric tube with interrupted 5-0 Vicryl. Results: All procedures were completed thoracoscopically without major peroperative complications. The mean operating time was 198 minutes (range, 138 to 250). One patient had a major leak, resulting in a stormy postoperative course, but the leak healed on conservative treatment. This patient and 3 others had stenosis requiring dilatation, respectively, 3, 6, 12, and 1 times. The babies were fed after a median period of 8 days. The median hospital stay was 13 days. Conclusions: Thoracoscopic repair of esophageal atresia with distal fistula is feasible. Larger series are needed to determine the exact place of the thoracoscopic approach. J Pediatr Surg 37:192-196. Copyright © 2002 by W.B. Saunders Company.