In an attempt to find a noninvasive way to improve the efficacy of skin optical clearing with topical application of optical clearing agents (OCA), we exploited the effect of ultrasound on optical clearing of intact skin in vitro Changes in optical transmittance and diffuse reflectance of the porcine skin under different treatment procedures were measured by a UV/Vis/NIR spectrophotometer. Clearing capability of glycerol or propylene glycol was much improved with the simultaneous application of ultrasound with a frequency of 1 MHz and a power of 0.75 W over a 3-cm probe. Light transmittance at 470 and 1276 nm increased by 112%-128% and 54%-65%, respectively. The most significant effect was seen where skin was treated with the combination of ultrasound and the chemical enhancer azone, resulting in a 2.3-fold increase of optical clearing at 1276 nm. We demonstrate the feasibility of using sonophoretic delivery methods to improve skin optical clearing with topical application of OCA.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.