Abstract
AbstractWe present a feasibility study of fast events parameters estimation algorithms regarding their execution time. It is the first stage of procedure used on data gathered from gas electron multiplier (GEM) detector for diagnostic of plasma impurities. Measured execution times are estimates of achievable times for future and more complex algorithms. The work covers usage of Intel Xeon and Intel Xeon Phi - high-performance computing (HPC) devices as a possible replacement for FPGA with highlighted advantages and disadvantages. Results show that less than 10 ms feedback loop can be obtained with the usage of 25% hardware resources in Intel Xeon or 10% resources in Intel Xeon Phi which leaves space for future increase of algorithms complexity. Moreover, this work contains a simplified overview of basic problems in actual measurement systems for diagnostic of plasma impurities, and emerging trends in developed solutions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Electronics and Telecommunications
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.