Abstract

CBCT-based online adaptive radiotherapy allows treatment plans to be tailored to the anatomy of the day. For this purpose, dose optimization and computation are performed on a synthetic CT (sCT), i.e., a density map of the planning CT deformably registered onto the acquired CBCT. Plan-specific quality assurance of adaptive treatment sessions is currently limited to the vendors own secondary dose calculation on the sCT. The use of EPID recordings promises to detect deviations in beam delivery or patient position, incorrect sCT data and anatomical changes. The purpose of this research was to evaluate the feasibility of using a new commercial technology available for in-vivo dose reconstruction based on EPID exit beam measurements. EPID images were recorded from on-couch adapted, hypofractionated treatment plans created for a prostate patient. Secondary dose calculation of the adapted plan and 3D reconstructions from EPID images of the absolute dose delivered to the patient were performed with the in-vivo dosimetry system. Comparison of reconstructed and planned delivery was conducted by means of gamma analysis and DVH metrics. Comparisons of the intended plan to a second volumetric check (collapsed cone - CC algorithm), and to the EPID in-vivo calculation, produced gamma passing rates averaged over the 7 fractions of 98.3% and 88.8% at TG-218/219 recommended criteria (Table 1). DVH metrics showed average deviations of -2.9% / -3.3% for PTV D95% and -1.2% / -0.2% for PTV D50% between intended dose and secondary / EPID in-vivo dose. The pronounced discrepancies for fraction 3 in terms of both reduced gamma passing rates and increased deviations for the EPID reconstructed dose coincide with a large air cavity in the rectum showing up in the patient's CBCT prior to treatment. Secondary dose calculation based on the density information of the CBCT as an additional option for QA confirmed origin and magnitude of this effect. In-vivo EPID dosimetry of adaptive clinical plans is feasible. It was shown exemplary that it reveals fractions with noticeable anatomical changes between the sCT and the patient anatomy during treatment. As new recommendations were published on in-vivo dosimetry through TG 307, the development of new clinical tools and evaluation of existing commercial solutions is essential, also in the context of the growing use of on-couch adaptive technology.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call