Abstract

Cerebral sonography (CS) through the anterior fontanelle is a neonatal brain imaging method that has become an integral part of modern neonatal bedside care for both screening and diagnostic purposes. Premature infants with cognitive delay have a reduction in cerebellar size at term corrected age on magnetic resonance imaging (MRI). We aimed to determine the level of agreement between postnatal MRI and CS for cerebellar biometry and to determine the level of agreement within one and between different examiners. Cerebellar sonography and MRI measurements of the cerebellum from 30 term infants was assessed by Bland-Altman plots. Measurements between both modalities were compared using Wilcoxon's signed rank test. A p-value < 0.01 was considered statistically significant. Intraclass correlation coefficients (ICC) for intra- and interrater reliabilities of CS measurements were calculated. There was no statistically significant difference between CS and MRI for linear measurements, but the measurements of perimeter and surface area differed significantly between the two techniques. There was a systematic bias between both modalities for most measurements except for anterior-posterior (AP) width and vermis height (VH). For measurements that were not statistically different from MRI, we found excellent intrarater ICC for the AP width, VH, and cerebellar width. The interrater ICC was excellent for the AP width and VH, but poor for the transverse cerebellar width. With a strict imaging protocol, cerebellar measurements of the AP width and the VH can be used as an alternative to MRI for diagnostic-screening purposes in a neonatal department where multiple clinicians perform bedside CS. · Abnormal cerebellar growth and injuries affect neurodevelopmental outcome.. · Cerebral sonography through the anterior fontanelle is used for bedside imaging.. · Postnatal sonographic cerebellar measurements are not validated against MRI.. · Measuring vermis height and anterior-posterior width are reliable.. · Measuring transverse cerebellar width through anterior fontanelle is unreliable..

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.