Abstract

Feasibility of a ceiling-mounted assist device of the air-purifier for removal of airborne allergenic pollen grains is investigated by both turbulent flow and particle-tracking calculations. The device is mounted straight above the air-purifier and it collects suspended pollen grains in the exhaust flow of the air-purifier. It is found from the turbulent flow calculation that the flow rate of the assist device should be larger than that of the air-purifier. Otherwise the upward air flows around the assist device, and pollen grains move along the surrounding flow; they are never removed from the air. We also found about 40% improvement of the pollen removal efficiency by installing the assist device.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.