Abstract
Advances in cold storage and transport technologies have seen the development of automatic ventilation technology and dynamic controlled atmosphere (DCA). Instead of using the commonly used fixed, open air exchange ventilation (AirEx) at 15,000 L fresh air h(-1) during shipping of Proteaceae stems, the new technologies restrict ventilation to gas concentrations that are near the set limits. Ventilation only occurs at O-2 levels near the lower O-2 limit (LOL) and at levels below the CO2 toxicity limit of the products. The gas exchange dynamics and ventilation requirements of sea freighted Protea cut flowers from South Africa (SA) are largely unknown, which has been a limiting factor to the introduction of automatic ventilation as an alternative within sea freight shipping. Furthermore, the suitability of current sea freight technology for Proteaceae cut flowers that are shipped from SA to Europe is under question due to inconsistencies in product quality upon arrival at their markets. The low storage temperature, AirEx ventilation and lengthy cold storage period have been identified as possible causes of quality loss during sea freight. The feasibility of the use of automatic ventilation technology during exports to distant markets was evaluated by determining the LOL values of the Protea cut flower products when stored at low O-2 concentration and assessing the toxicity tolerance in high CO2 atmosphere. Determination of the LOL was done using a fluorescence interactive response monitor (FIRM) sensor attached to a DCA system. High CO2 tolerance was tested by increasing the CO2 concentration stepwise from 5 to 15% CO2 atmospheric concentration (5-10-15% CO2). The LOL values of the products ranged from 0.08-0.25% O-2. AirEx atmosphere led to higher moisture loss than high CO2 atmosphere, with insignificant differences between AirEx and low O-2 atmosphere. The products stored in AirEx and high CO2 atmospheres had comparable flower head and leaf quality. The flower head and leaf quality of products stored in low O-2 was better than that of products stored in AirEx atmosphere.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.