Abstract

The polyvinyl alcohol method (PVAL) is known as an effective technique to thoroughly collect traces of gunshot residue (GSR) from different surfaces, e.g., from hands or gunshot wounds. Despite obvious advantages over other methods using adhesive tapes, PVAL is still not widely accepted and applied in routine case work due to a required acquisition time of at least 15 to 20 min for a single shooting hand. In this study, the feasibility of a modified procedure taking 6 to 8 min per sample is tested within the frame of an experimental setting including (1) the collection of GSR from experimental gunshots with a semi-automatic pistol and lead-containing primer ammunition and (2) a simple experimental setting involving dry and moist artificial blood traces. In a third step, samples of four gun-associated suicide cases and one attempted suicide case were taken and analyzed. Furthermore, an exemplary implementation into a work flow of modern instrumental techniques of GSR analysis is presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.