Abstract

AimTo determine the feasibility and potential benefit of a full cardiac magnetic resonance (CMR) work-up for assessing the location of scarred myocardium and the region of latest contraction (LCR) in patients with ischaemic cardiomyopathy (ICM) undergoing cardiac resynchronisation therapy (CRT).MethodsIn 30 patients, scar identification and contraction timing analysis was retrospectively performed on CMR images. Fluoroscopic left ventricular (LV) lead positions were scored with respect to scar location, and when placed outside scar, with respect to the LCR. The association between the lead position with respect to scar, the LCR and echocardiographic LV end-systolic volume (LVESV) reduction was subsequently evaluated.ResultsThe CMR work-up was feasible in all but one patient, in whom image quality was poor. Scar and contraction timing data were succesfully displayed on 36-segment cardiac bullseye plots. Patients with leads placed outside scar had larger LVESV reduction (−21 ± 21%, n = 19) compared to patients with leads within scar (1 ± 25%, n = 11), yet total scar burden was higher in the latter group. There was a trend towards larger LVESV reduction in patients with leads in the scar-free LCR, compared to leads situated in scar-free segments but not in the LCR (−34 ± 14% vs −15 ± 21%, p = 0.06).ConclusionsThe degree of reverse remodelling was larger in patients with leads situated in a scar-free LCR. In patients with leads situated within scar there was a neutral effect on reverse remodelling, which can be caused both by higher scar burden or lead position. These findings demonstrate the feasibility of a CMR work-up and potential benefit in ICM patients undergoing CRT.

Highlights

  • Cardiac resynchronisation therapy (CRT) is an effective therapy for patients with chronic heart failure, impaired left ventricular (LV) ejection fraction and prolonged QRS duration [1]

  • Patients with leads placed outside scar had larger LV end-systolic volume (LVESV) reduction (–21 ± 21%, n = 19) compared to patients with leads within scar (1 ± 25%, n = 11), yet total scar burden was higher in the latter group

  • There was a trend towards larger LVESV reduction in patients with leads in the scar-free latest contraction (LCR), compared to leads situated in scar-free segments but not in the LCR (–34 ± 14% vs –15 ± 21%, p = 0.06)

Read more

Summary

Introduction

Cardiac resynchronisation therapy (CRT) is an effective therapy for patients with chronic heart failure, impaired left ventricular (LV) ejection fraction and prolonged QRS duration [1]. With advancements in implanting techniques, such as real-time image-guided LV lead delivery, the snare technique and multipoint pacing, tailor-made individualised therapy has become available to patients undergoing CRT [13,14,15,16]. These advances call for image post-processing techiques that can determine the location of myocardial scar and delayed contraction, so that these areas can either be avoided or targeted. We assessed the effect of tissue characteristics (e.g. scar and delayed contraction) at the LV pacing electrode on LV reverse remodelling after CRT

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call