Abstract

A new experimental protocol was applied utilizing a simplified postural control model. Multiple constructs were tested nondestructively by interconnecting segmental rods to screws. To investigate how posture and distribution of segmental angles under physiological loads are affected by combined cervical arthroplasty and fusion. Previous studies of biomechanics of multilevel arthroplasty have focused on range of motion and intradiscal pressure. No previous study has investigated postural changes and segmental angle distribution. In 7 human cadaveric C3-T1 specimens, C4-C5, C5-C6, and C6-C7 disks were replaced with ProDisc-C (Synthes). Combinations of fusion (f) adjacent to arthroplasty (A) were simulated at C4-C5, C5-C6, and C6-C7, respectively: fAA, AfA, AAf, ffA, fAf, Aff, fff. C3-C4 and C7-T1 remained intact. A compressive belt apparatus simulated normal muscle cocontraction and gravitational preload; C3-C4, C4-C5, C5-C6, C6-C7, and C7-T1 motions were tracked independently. Parameters studied were segmental postural compensation, neutral buckling, and shift in sagittal plane instantaneous axis of rotation (IAR). With one or more levels unfused, the arthroplasty levels preferentially moved toward upright posture before the intact levels. Neutral buckling was greatest for 3-level arthroplasty, less for 2-level arthroplasty, and least for 1-level arthroplasty. Among the three 1-level arthroplasty groups (ffA, fAf, Aff), arthroplasty at the caudalmost level resulted in significantly greater buckling than with arthroplasty rostralmost or at mid-segment (P<0.04, analysis of variance/Holm-Sidak). Although IAR location was related to buckling, this correlation did not reach significance (P=0.112). Arthroplasty levels provide the "path of least resistance," through which the initial motion is more likely to occur. The tendency for specimens to buckle under vertical compression became greater with more arthroplasty levels. Buckling appeared more severe with arthroplasty more caudal. Buckling only moderately correlated to shifts in IAR, meaning slight malpositioning of the devices would not necessarily cause buckling.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.