To study the feasibility of using municipal sewage as a reserve water source for oilfield reinjection, the water sample treated by the municipal sewage treatment plant and the produced water of the Chang 2 reservoir were taken as the research objects. Through the analysis of water quality and compatibility, the optimal ratio of reinjection water samples was determined. At the same time, the clay swelling experiment and reservoir damage experiment were carried out. The experimental results show that the salinity of municipal sewage is low, and the content of scale ions is low. When the ratio of produced water to municipal sewage is 7:3, the scale formation amount can reach 42.5 mg.L-1, and when the scale inhibitor is added, the scale formation amount can be reduced to 10.4 mg.L-1. The mixed water sample will not cause clay expansion. Meanwhile, Chang 2 reservoir is moderately weak water sensitive and weak acid sensitive. The oil content, suspended solids content, and median particle size of the mixed water sample during reinjection should be controlled at 5 mg.L-1, 5 mg.L-1, and 5 μm to ensure that the reinjected water sample does not cause damage to the reservoir.