Abstract
Unit step response (USR) parameters of a circuit for measuring chopped lightning impulse voltages are calculated using the finite-difference time-domain method for solving Maxwell's equations, and compared with those of a USR-measuring circuit recommended by the International Electrotechnical Commission (IEC). Although the circuit for measuring chopped lightning impulse voltages is quite different from the IEC-recommended USR measuring circuit, USR parameters calculated for the former circuit are not much different from those calculated for the latter circuit except the case when the former circuit includes both a low-impedance impulse high voltage generator and a damping resistor.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.