Abstract

This paper investigates smoke movement and its stratification in a lay-by of a 900 m long road tunnel by computer simulation using Fire Dynamics Simulator. The lay-by is located upstream of the fire in its vicinity. The influence of lay-by geometry on smoke spread is evaluated by comparison with a fictional tunnel without lay-by. Several fire scenarios with various tunnel slopes and heat release rates of fire in the tunnels without and with the lay-by are considered. The most significant breaking of smoke stratification and decrease of visibility in the area of the lay-by can be observed in the case of zero slope tunnel for more intensive fires with significant length of backlayering. Several other features of smoke spread in the lay-by are analysed as well. The parallel calculations were performed on a high-performance computer cluster.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.