Abstract
This paper introduce faults diagnosis based on current analysis. The current spectrum of a three phases and single phase induction motor and also of a DC motor, are analyzed in order to achieve information for the detection of different faults. In order to perform the diagnosis we analyzed signals of current from the ampere sensor. The Fast Fourier Transform is applied to the signals acquired. We observe significant current spectrum differences between healthy motors and motors with faults. The high-frequency spectral analysis of current provides a method to detect bearing faults, broken rotor bars faults and commutator short circuit and presence of a displaced permanent magnet out of poles in polar axe. The system developed is scalable to different power ratings and it has been successfully tested with data from 0.75kW three phases induction motor, 0.65kW single phase induction motor and DC motor with permanent magnet.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.