Abstract

This paper studies fault-tolerant operation of multipole single-phase switched reluctance generators (SRGs), in particular, an 8/8-pole switched reluctance machine. The multipole single-phase SRG system is advantageous for reduced cost and higher efficiency compared to polyphase equivalents. However, using the classical phase-leg topology, a phase fault may prevent generating operation completely, since redundancy in the number of phases does not exist like polyphase systems. A new power converter topology which connects two coil banks in parallel is proposed for higher fault tolerance with minimum additional cost. Faulty coils can be disconnected with the proposed converter and the SRG can continue generating operation after coil faults with reduced output power. Output power per coil current under faults is studied. Open- and short-circuit coils are studied through linear analysis, finite-element analysis and static torque measurement. Generated currents under faults with the proposed converter are measured. The capability of the system to disconnect faulty coils dynamically is also shown.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.