Abstract
AbstractThis paper presents a new space phasor modulation (SPM) scheme for the operation of the H‐bridge multicell inverter under fault conditions. The topology of this inverter consists of several single‐phase H‐bridge inverters which can be independently bypassed if a fault is detected. As this action may result in an asymmetrical inverter topology, a new method based on the SPM is proposed to avoid voltage unbalances. Simulations and experimental results obtained in a five‐level multicell inverter prototype validate the proposed fault‐tolerant method. Copyright © 2007 John Wiley & Sons, Ltd.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.