Abstract

Operation and analysis of delta-connected ac motor-drive systems under fault-tolerant open-phase mode of operation is introduced in this paper for both scalar- and vector-controlled motor-drive systems. This technique enables the operation of the three-phase motor upon a failure in one of its phases without the need of a special fault-detection algorithm. It is mainly used to significantly mitigate torque pulsations, which are caused by an open-delta configuration in the stator windings. The performance of the fault-tolerant system was verified using a detailed time stepping finite element simulation as well experimental tests for a 5-hp 460-V induction motor-drive system and the results are presented in this paper This paper also compares the operation of this fault-tolerant mode of operation for the cases of scalar-controlled and closed-loop vector-controlled motor-drive systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.