Abstract

In this paper a continuous fault tolerant control allocation is proposed. This approach is based on a uniform High-Order Sliding-Mode Observer where only measurable outputs are used. The fault tolerant control scheme is developed using, for the first time, a continuous integral sliding-mode and a fixed control allocation technique which provides an approximate estimation of matched faults. The conditions for stability are found by ensuring the stability of the closed loop system in the presence of possible faults in the components, and actuator faults or failures. The effectiveness of the proposed approach is verified through simulation of a linear version of the benchmark B747—100/200 civil aircraft model.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.