Abstract

Steam-induced vibration fault seriously affects the reliable operation of supercritical steam turbine. A lot of actual cases of steam-induced vibration of steam turbine were collected in this work. Based on the cases, steam-induced vibration fault was statistical and classified by fault severity, fault reason, occurrence load and happened time. The results show that steam-induced vibration usually occurs after turbine runs one year later and turbine is with a high load. Oil temperature change is the main running parameters which affect steam-induced vibration. Distribute steam mechanism, especially improper opening and order of adjustment valve, is the most important factor causing steam-induced vibration fault. Meanwhile, based on the FMEA method, fault mode of steam-induced vibration was analyzed in detail.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.