Abstract
Taking TWERD frequency converter as research object, the working principle and fault types of three-phase SPWM inverter are analyzed. Its output line voltage waveform in normal operation and fault condition is studied. According to the fault information and the different data of input and load changes, the frequency converter output line voltage waveform is decomposed by wavelet transform. The low frequency energy value is picked-up and regards it as eigenvector. The mapping relationship between eigenvector and fault types are established by BP neural network, the fault bridge and fault location of frequency converter are found. Simulation results show that the diagnosis accuracy is 96.5% after training 46 times. Fast convergence speed and high precision is obtained.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.